4” Three-phase encapsulated Water-Cooled Franklin motors
Product features:
-Hermetically sealed stator
-Water lubricated radial and thrust bearing
-Corrosion resistant AISI 304 SS material
-Removable Water Bloc™ motor cable connector
-Anti-track, self healing stator resin prevents motor burn out
-High efficiency electrical design (lower operating cost, cooler winding temperature)
-Non-contaminating, water-filled design
-KTW-approved material
Standard
-0,37 – 7,5 kW
-380V - 415V / 50 Hz
-Thrust capacity: 1.500N; 3.000N; 4.000N; 6.500N
Pump Protector – DRP will protect the motor from:
-Dry running (with automatic restart).
-Frequent starts and stops.
-Overload & surges, such as from lighting.
-Low voltage protection.
Specifications
4” NEMA flange
Degree of protection: IP 68
Insulation: Cl. B ambient temp.: 30°C
Cooling flow: min. 8cm/sec.
Starts/h: 20
Mounting: Vertical/horizontal Voltage tolerance: +6% / -10% UN
Motor protection: Select thermal overloads according to EN 60947-4-1
Trip time < 10sec. at 5 x IN
On three-phase Franklin htF motor for starting, running and overload protection must be provided by users. Motor protection must be guaranteed in accordance with EN60947-4-1 trip time <10 s a 5 x IN norms.
|

|
| | | |